Proline Prowirl 73F |
|
Vortex Flow Measuring
System - The reliable flow measurement of gas, steam
and liquids. Two-Wire Saturated Steam Mass Flowmeter. |
|
*
Application |
For universal volume
or mass flow measurement of steam, water (according
to IAPWS-IF97 ASME), natural gas (according to AGA
NX-19), compressed air and other liquids or gases.
Maximum application range:
fluid temperatures from -200 to +400 ¡ÆC [-330 to
+750¡ÆF]
pressure ratings up to PN40 [Cl300] (higher pressure
ratings in preparation) |
|
|
|
Approvals for hazardous
areas:
ATEX, FM, CSA, TIIS Connection to all
prevalent systems:
HART, PROFIBUS PA, FOUNDATION Fieldbus Relevant
safety aspects:
PED, SIL-1 Your benefits
Prowirl 73 offers a complete measuring point
for saturated steam or liquid mass in a single device:
mass flow is calculated from the measured variables of
volume flow and temperature in the integrated flow computer.
For superheated steam or gas applications an external
pressure value can read in optionally, for delta heat
applications an external temperature value can be read
in.
The instrument can be ordered pre-programmed (customer
or application specific)
he Prowirl sensor is robust, reliable
and proven in more than a 100'000 applications. It offers:
multivariable flow measurement in compact design
high robustness against:
- vibrations (above 1 g in all axes)
- temperature shocks (>150 K/s)
- clogging fluids
- water hammer
no maintenance, no moving parts, no zero point drift
|
|
|
|
|
|
|