Untitled Document
|
|
|
|
|
|
Untitled Document
|
|
|
Prosonic S - Sensors
FDU91, FDU91F, FDU92, FDU93, FDU95,
FDU96 |
|
*
Application |
Continuous,
non-contact level measurement of fluids, pastes, sludges and
powdery to coarse bulk materials
Flow measurement in open channels and measuring weirs
Bitmap Suited for explosion hazardous areas |
|
|
*
The most important technical data |
Max. measuring range
FDU91/91F 10 m in fluids
5 m in bulk materials
Max. measuring range FDU92 20 m in fluids
10 m in bulk materials
Max. measuring range FDU93 25 m in fluids
15 m in bulk materials
Max. measuring range FDU95 45 m in bulk materials
Max. measuring range FDU96 70 m in bulk materials
Min. process temperature -40 ¡ÆC
Max. process temperature +80 - +150 ¡ÆC (depending
on the sensor) Bitmap
Min. process pressure 0.7 bar
Max. process pressure 1.5 bar - 4 bar (depending
on the sensor)
Certificates ATEX, CSA, FM TIIS (for details refer
to Technical Information TI396F) |
|
|
|
Prosonic M FMU40, FMU41, FMU42, FMU43, FMU44 |
Compact
transmitters for non-contact level measurements of fluids, pastes
and coarse bulk materials |
|
Areas
of application
Continuous, non-contact level measurement in fluids, pastes,
sullages and coarse bulk materials
Flow measurement in open channels and measuring weirs
System integration via HART (4 ... 20 mA), PROFIBUS PA or FOUNDATION
Fieldbus |
|
The most important
technical data
Max. measuring range FMU 40 5 m in fluids
2 m in bulk materials
Max. measuring range FMU 41 8 m in fluids
3.5 m in bulk materials
Max. measuring range FMU 42 10 m in fluids
5 m in bulk materials
Max. measuring range FMU 43 15 m in fluids
7 m in bulk materials
Max. measuring range FMU44 20 m in fluids
10 m in bulk materials
Process temperature -40 ¡ÆC ... +80 ¡ÆC
Ambient temperature -40 ¡ÆC ... +80 ¡ÆC
Process pressure FMU 40/41 3 bar abs.
Process pressure FMU 42/43/44 2.5 bar abs. Bitmap
Certificates ATEX, FM, CSA, TIIS
(for details refer to Technical Information TI 365F)
|
|
|
|
|
|
|
|
|